2 Parameters
2.2 List of parameters
SINAMICS G130/G150
256 List Manual (LH2), 07/2016, A5E03263479A
Description: Sets the bidirectional digital inputs/outputs as an input or output.
Notice: Regarding the terminal designation:
The first designation is valid for CU320, the second for CU310.
Note: DI/DO: Bidirectional Digital Input/Output
Description: Displays the access authority at the digital outputs.
Bit = 1:
The control has access authority to the digital output via PROFIBUS or direct access.
Bit = 0:
The drive has access authority to the digital output or the digital input/output is not set as digital output or is not
available.
Dependency: Refer to: p0728, p0738, p0739, p0740, p0741, p0742, p0743, p0744, p0745, r0747, p0748
Notice: Regarding the terminal designation:
The first designation is valid for CU320, the second for CU310.
Note: The DI/DO must be connected as output (p0728).
DI/DO: Bidirectional Digital Input/Output
p0728 CU set input or output / CU DI or DO
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: T Calculated: - Access level: 1
Data type: Unsigned32 Dyn. index: - Func. diagram: 2119, 2030,
2031, 2130, 2131, 2132, 2133
P-Group: Commands Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0000 0000 0000 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
08 DI/DO 8 (X122.9/X121.7) Output Input -
09 DI/DO 9 (X122.10/X121.8) Output Input -
10 DI/DO 10 (X122.12/X121.10) Output Input -
11 DI/DO 11 (X122.13/X121.11) Output Input -
12 DI/DO 12 (X132.9/X131.1) Output Input -
13 DI/DO 13 (X132.10/X131.2) Output Input -
14 DI/DO 14 (X132.12/X131.4) Output Input -
15 DI/DO 15 (X132.13/X131.5) Output Input -
r0729 CU digital outputs access authority / CU DO acc_auth
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: - Calculated: - Access level: 1
Data type: Unsigned32 Dyn. index: - Func. diagram: 2030, 2031,
2130, 2131, 2132, 2133
P-Group: Commands Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
08 DI/DO 8 (X122.9/X121.7) High Low -
09 DI/DO 9 (X122.10/X121.8) High Low -
10 DI/DO 10 (X122.12/X121.10) High Low -
11 DI/DO 11 (X122.13/X121.11) High Low -
12 DI/DO 12 (X132.9/X131.1) High Low -
13 DI/DO 13 (X132.10/X131.2) High Low -
14 DI/DO 14 (X132.12/X131.4) High Low -
15 DI/DO 15 (X132.13/X131.5) High Low -