2 Parameters
2.2 List of parameters
SINAMICS G130/G150
616 List Manual (LH2), 07/2016, A5E03263479A
Description: Displays a fault due to the excessively high temperature.
1 signal:
The connected temperature sensor (X21.1, X21.2) signals an overtemperature.
Recommendation: Measure the braking resistor temperature using the temperature sensor.
Description: Displays the shutdown due to the excessively high temperature.
1 signal:
The connected temperature sensor (X21.1, X21.2) signals an overtemperature. The highest permissible temperature
at the connected temperature sensor has been exceeded and results in a shutdown.
Dependency: Refer to: F06908
Description: Displays an Uce fault in the internal Braking Module.
1 signal:
An Uce fault is present in the internal Braking Module.
Dependency: Refer to: F06909
Description: Sets the activation for the line-drive synchronization.
Value: 0: Sync-line-drive deactivated
1: Sync-line-drive activated VSM-INT
Dependency: Refer to: p3801, p3802
Caution: If there is only one VSM being used, this can either be used for line synchronization or for a flying restart. If the VSM
was connected to the line supply, then flying restart should be deselected in p1200. If the VSM was connected at the
output (motor side), then line synchronization should be deactivated using p3800.
Line synchronization (first VSM connected with the line supply) and also flying restart (second VSM connected to the
motor terminals) can only be used if two VSMs are assigned to the Motor Module.
r3687 BO: Digital Braking Module pre-alarm overtemperature / Dig BM A overtemp
B_INF Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r3688 BO: Braking Module internal overtemperature shutdown / BM int temp shutd
B_INF Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r3689 BO: Digital Braking Module Uce fault / Dig BM Uce fault
B_INF Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
p3800[0...n] Sync-line-drive activation / Sync act
VECTOR_G Can be changed: T Calculated: - Access level: 2
Data type: Integer16 Dyn. index: DDS, p0180 Func. diagram: 7020
P-Group: Functions Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0