EasyManua.ls Logo

Siemens G130 - r0064 CO: Speed controller system deviation; n_ctrl sys dev; r0065 Slip frequency; f_Slip; r0066 CO: Output frequency; f_outp; r0067 CO: Output current maximum; I_outp max

Siemens G130
1976 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Parameters
2.2 List of parameters
SINAMICS G130/G150
64 List Manual (LH2), 07/2016, A5E03263479A
Description: Displays the actual system deviation of the speed controller.
Note: In servo control mode with active reference model, the system deviation to the P component of the speed controller is
displayed.
Description: Displays the slip frequency for induction motors (ASM).
Description: Display and connector output for the output frequency of the Motor Module.
Dependency: Refer to: r0024
Note: The output frequency is available smoothed (r0024) and unsmoothed (r0066).
Description: Display and connector output for the maximum output current of the power unit.
Dependency: The maximum output current is determined by the parameterized current limit and the motor and converter thermal
protection.
Refer to: p0290, p0640
r0064 CO: Speed controller system deviation / n_ctrl sys dev
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 5040, 6040
P-Group: Displays, signals Unit group: 3_1 Unit selection: p0505
Not for motor type: - Scaling: p2000 Expert list: 1
Min Max Factory setting
- [rpm] - [rpm] - [rpm]
r0065 Slip frequency / f_Slip
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6310, 6700,
6727, 6730, 6732
P-Group: Displays, signals Unit group: 2_1 Unit selection: p0505
Not for motor type: - Scaling: p2000 Expert list: 1
Min Max Factory setting
- [Hz] - [Hz] - [Hz]
r0066 CO: Output frequency / f_outp
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 5300, 5730,
6300, 6310, 6730, 6731, 6799
P-Group: Displays, signals Unit group: 2_1 Unit selection: p0505
Not for motor type: - Scaling: p2000 Expert list: 1
Min Max Factory setting
- [Hz] - [Hz] - [Hz]
r0067 CO: Output current maximum / I_outp max
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 5722, 6300,
6301, 6640
P-Group: Displays, signals Unit group: 6_2 Unit selection: p0505
Not for motor type: - Scaling: p2002 Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]

Table of Contents