Siemens G130 - p4073[0...1] TB30 analog outputs smoothing time constant; TB30 AO T_smooth; r4074[0...1] TM31 analog outputs current output voltage;current; TM31 AO U;I_outp; r4074[0...1] TB30 analog outputs actual output voltage; TB30 AO U_outp; p4075[0...1] TM31 analog outputs activate absolute value generation; TM31 AO absVal act

Siemens G130
1976 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
657
2 Parameters
2.2 List of parameters
Description: Sets the smoothing time constant of the 1st order lowpass filter for the analog outputs of the Terminal Board 30
(TB30).
Index: [0] = AO 0 (X482.5/X482.6)
[1] = AO 1 (X482.7/X482.8)
Description: Displays the actual output voltage in V when set as voltage output.
Displays the actual output voltage in mA when set as current output.
Index: [0] = AO 0 (X522.1, X522.2, X522.3)
[1] = AO 1 (X522.4, X522.5, X522.6)
Dependency: The type of the analog output AO x (voltage or current output) is set using p4076.
Refer to: r4076, p4076
Note: AO: Analog Output
Description: Displays the actual output voltage at the analog outputs of the Terminal Board 30 (TB30).
Index: [0] = AO 0 (X482.5/X482.6)
[1] = AO 1 (X482.7/X482.8)
Description: Activates the absolute value generation for the analog outputs of Terminal Module 31 (TM31).
Value: 0: No absolute value generation
1: Absolute value generation switched in
Index: [0] = AO 0 (X522.1, X522.2, X522.3)
[1] = AO 1 (X522.4, X522.5, X522.6)
p4073[0...1] TB30 analog outputs smoothing time constant / TB30 AO T_smooth
TB30 Can be changed: U, T Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 9106
P-Group: Terminals Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.0 [ms] 1000.0 [ms] 0.0 [ms]
r4074[0...1] TM31 analog outputs current output voltage/current / TM31 AO U/I_outp
TM31 Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 9572
P-Group: Terminals Unit group: - Unit selection: -
Not for motor type: - Scaling: p2001 Expert list: 1
Min Max Factory setting
- - -
r4074[0...1] TB30 analog outputs actual output voltage / TB30 AO U_outp
TB30 Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 9106
P-Group: Terminals Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
p4075[0...1] TM31 analog outputs activate absolute value generation / TM31 AO absVal act
TM31 Can be changed: T Calculated: - Access level: 3
Data type: Integer16 Dyn. index: - Func. diagram: 9572
P-Group: Terminals Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0