Siemens G130 - p4833[0...2] Function generator offset scaling; FG offset scal; r4834[0...4] CO: Function generator free measurement output signal; FG fr MeasFct outp; p4835[0...4] Function generator free measurement function scaling; FG fr MeasFct scal; p4840[0...1] MTrace cycle number setting; Cycle number

Siemens G130
1976 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Parameters
2.2 List of parameters
SINAMICS G130/G150
728 List Manual (LH2), 07/2016, A5E03263479A
Description: Sets the scaling for the offset of the signal waveforms separately for each output channel.
The value cannot be changed while the function generator is running.
Index: [0] = First drive for connection
[1] = Second drive for connection
[2] = Third drive for connection
Description: Displays the output signal for the free measurement function.
Index: [0] = Signal 1
[1] = Signal 2
[2] = Signal 3
[3] = Signal 4
[4] = Signal 5
Dependency: Refer to: p4810
Note: The signals are only output in the "free measurement function" operating mode (p4810 = 6)
Description: Sets the scaling of the output signals for the free measurement function.
Index: [0] = Signal 1
[1] = Signal 2
[2] = Signal 3
[3] = Signal 4
[4] = Signal 5
Note: The parameter cannot be changed when the measurement function has been started (r4706 = 2, 3).
Description: Sets the number of cycles of a multiple trace.
The multiple trace is deactivated with a value = 0.
p4833[0...2] Function generator offset scaling / FG offset scal
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
-340.28235E36 [%] 340.28235E36 [%] 100.00000 [%]
r4834[0...4] CO: Function generator free measurement output signal / FG fr MeasFct outp
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 0
Min Max Factory setting
- [%] - [%] - [%]
p4835[0...4] Function generator free measurement function scaling / FG fr MeasFct scal
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
-200.00000 [%] 200.00000 [%] 100.00000 [%]
p4840[0...1] MTrace cycle number setting / Cycle number
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
0 4294967295 0