SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
733
2 Parameters
2.2 List of parameters
Description: Displays the IDs of all the invalid Technology Extensions installed on the memory card/device memory.
r4978[0...8]: Identifier of invalid Technology Extension 1
r4978[9...17]: Identifier of invalid Technology Extension 2, ...
Dependency: Refer to: r4975, r4976, r4979
Notice: An index cannot be accessed if there is no valid Technology Extension available.
Note: TEC: Technology Extension
Description: Displays the error code of the invalid Technology Extensions installed on the memory card/device memory.
r4979[0]: Fault value of Technology Extension 1
r4979[1]: Fault value of Technology Extension 2, ...
Dependency: Refer to: r4975, r4976, r4978
Notice: An index cannot be accessed if there is no valid Technology Extension available.
Note: TEC: Technology Extension
The value in the error code must be interpreted in binary form. The bits have the following meaning:
Bit 0: Incompatible version of the TEC interface.
Bit 1: Technology Extension could not be loaded.
Bit 2: Incorrect description files.
Bit 3: Technology Extension does not define a CPU type.
Bit 4: Technology Extension for this device not available (incorrect CPU type).
Bit 5: Technology Extension for this device not available (incorrect type ID).
Bit 6: Incorrect description files (Const/Startup incompatible).
Description: Displays the number of Technology Extensions installed on the memory card/device memory.
Dependency: Refer to: r4986, r4987, r4988, r4989, r4990, r4991, r4992, r4993, r4994
Note: TEC: Technology Extension
r4978[0...n] TEC invalid identifier / TEC inval ID
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: - Calculated: - Access level: 4
Data type: Unsigned8 Dyn. index: r4976 Func. diagram: -
P-Group: OEM range Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r4979[0...n] TEC invalid error code / TEC inv error code
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: - Calculated: - Access level: 4
Data type: Unsigned32 Dyn. index: r4975 Func. diagram: -
P-Group: OEM range Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r4985 TEC number / TEC qty
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: - Calculated: - Access level: 4
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: OEM range Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 16 -