2 Parameters
2.2 List of parameters
SINAMICS G130/G150
742 List Manual (LH2), 07/2016, A5E03263479A
Dependency: Refer to: r0034
Note: Users cannot see and change parameter p0613 (only Siemens internal).
Description: Displays the alarm threshold for monitoring the motor temperature for motor temperature model 3.
This value is used to calculate the utilization display (p0034).
The parameter value is an image of p5390.
Dependency: Refer to: p5390
Refer to: F07011, A07012, A07014
Note: Users cannot see and change parameter p5390 (only Siemens internal).
Description: Sets the fault threshold for monitoring the motor temperature for motor temperature model 3.
Fault F07011 is output after the fault threshold is exceeded.
The parameter value is an image of p5391.
Dependency: Refer to: p5391
Refer to: F07011, A07012, A07014
Note: Users cannot see and change parameter p5391 (only Siemens internal).
Description: Displays the PROFIenergy mode ID of the effective energy-saving mode.
Value: 0: POWER OFF
2: Energy-saving mode 2
240: Operation
255: Ready
Note: Pe: PROFIenergy profiles
r5398[0...n] Mot_temp_mod 3 alarm threshold image p5390 / A thr image p5390
VECTOR_G Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: 8019
P-Group: Displays, signals Unit group: 21_1 Unit selection: p0505
Not for motor type: ASM, SESM, REL Scaling: - Expert list: 1
Min Max Factory setting
- [°C] - [°C] - [°C]
r5399[0...n] Mot_temp_mod 3 fault threshold image p5391 / F thr image p5391
VECTOR_G Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: 8019
P-Group: Displays, signals Unit group: 21_1 Unit selection: p0505
Not for motor type: ASM, SESM, REL Scaling: - Expert list: 1
Min Max Factory setting
- [°C] - [°C] - [°C]
r5600 Pe energy-saving mode ID / Pe mode ID
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: - Calculated: - Access level: 3
Data type: Integer16 Dyn. index: - Func. diagram: 2381, 2382
P-Group: Communications Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 255 -