Siemens G130 - r7021[0...n] CO: Par_circuit deviation current in phase V; Phase V curr dev; r7022[0...n] CO: Par_circuit deviation current in phase W; Phase W curr dev; r7025 CO: Par_circuit max. deviation currents phase U; Phase U Max i_dev; r7026 CO: Par_circuit max. deviation currents phase V; Phase V Max i_dev

Siemens G130
1976 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Parameters
2.2 List of parameters
SINAMICS G130/G150
754 List Manual (LH2), 07/2016, A5E03263479A
Description: Displays the deviation between the measured current actual value of phase V and the average value as peak value.
The maximum deviation from the average value is displayed in r7026.
Dependency: Refer to: r7020, r7022, r7026
Description: Displays the deviation between the measured current actual value of phase W and the average value as peak value.
The maximum deviation from the average value is displayed in r7027.
Dependency: Refer to: r7020, r7021, r7027
Description: Displays the maximum absolute deviation of the measured current actual values of phase U from the average value
as peak value.
The deviation of the individual currents from the average value is displayed in r7020.
Dependency: Refer to: r7020, r7026, r7027
Refer to: A05052
Description: Displays the maximum absolute deviation of the measured current actual values of phase V from the average value
as peak value.
The deviation of the individual currents from the average value is displayed in r7021.
Dependency: Refer to: r7021, r7025, r7027
Refer to: A05052
r7021[0...n] CO: Par_circuit deviation current in phase V / Phase V curr dev
VECTOR_G (Parallel) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Unit group: 6_5 Unit selection: p0505
Not for motor type: - Scaling: p2002 Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]
r7022[0...n] CO: Par_circuit deviation current in phase W / Phase W curr dev
VECTOR_G (Parallel) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Unit group: 6_5 Unit selection: p0505
Not for motor type: - Scaling: p2002 Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]
r7025 CO: Par_circuit max. deviation currents phase U / Phase U Max i_dev
VECTOR_G (Parallel) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Displays, signals Unit group: 6_5 Unit selection: p0505
Not for motor type: - Scaling: p2002 Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]
r7026 CO: Par_circuit max. deviation currents phase V / Phase V Max i_dev
VECTOR_G (Parallel) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Displays, signals Unit group: 6_5 Unit selection: p0505
Not for motor type: - Scaling: p2002 Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]