Siemens G130 - p7042[0...n] Par_circuit correction valve lockout time phase V; Comp t_lockout V; p7044[0...n] Par_circuit correction valve lockout time phase W; Comp t_lockout W; r7050[0...n] Par_circuit circulating current phase U; Circ_I_phase U; r7051[0...n] Par_circuit circulating current phase V; Circ_I_phase V

Siemens G130
1976 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
757
2 Parameters
2.2 List of parameters
Description: For the particular Motor Module, the correction time must be added to the valve lockout time to be compensated for
phase V (p1829).
The corrective value is used to compensate variations/spread in the valve lockout times of Motor Modules for a
parallel circuit configuration.
Dependency: Refer to: p1829
Description: For the particular Motor Module, the correction time must be added to the valve lockout time to be compensated for
phase W (p1830).
The corrective value is used to compensate variations/spread in the valve lockout times of Motor Modules for a
parallel circuit configuration.
Dependency: Refer to: p1830
Description: Displays the circulating current of phase U as peak value.
Description: Displays the circulating current of phase V as peak value.
Description: Displays the circulating current of phase W as peak value.
p7042[0...n] Par_circuit correction valve lockout time phase V / Comp t_lockout V
VECTOR_G (Parallel) Can be changed: U, T Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Modulation Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
-1000000.00 [µs] 1000000.00 [µs] 0.00 [µs]
p7044[0...n] Par_circuit correction valve lockout time phase W / Comp t_lockout W
VECTOR_G (Parallel) Can be changed: U, T Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Modulation Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
-1000000.00 [µs] 1000000.00 [µs] 0.00 [µs]
r7050[0...n] Par_circuit circulating current phase U / Circ_I_phase U
VECTOR_G (Parallel) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Unit group: 6_5 Unit selection: p0505
Not for motor type: - Scaling: p2002 Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]
r7051[0...n] Par_circuit circulating current phase V / Circ_I_phase V
VECTOR_G (Parallel) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Unit group: 6_5 Unit selection: p0505
Not for motor type: - Scaling: p2002 Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]
r7052[0...n] Par_circuit circulating current phase W / Circ_I_phase W
VECTOR_G (Parallel) Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Unit group: 6_5 Unit selection: p0505
Not for motor type: - Scaling: p2002 Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]