2 Parameters
2.2 List of parameters
SINAMICS G130/G150
766 List Manual (LH2), 07/2016, A5E03263479A
Description: Displays status word 1 of the power unit.
Description: Displays the rated power of the individual power units connected in parallel for various load duty cycles.
The sum of the rated powers of all power units connected in parallel is displayed in r0206.
Index: [0] = Rated value
[1] = Load duty cycle with low overload
[2] = Load duty cycle with high overload
[3] = S1 cont duty cyc
[4] = S6 load duty cycle
Dependency: The value is displayed in [kW] or [hp].
Refer to: p0100, p0205
Description: Displays the rated current of the individual power units connected in parallel for various load duty cycles.
The sum of the rated currents of all power units connected in parallel is displayed in r0207.
Index: [0] = Rated value
[1] = Load duty cycle with low overload
[2] = Load duty cycle with high overload
r7240[0...n] Par_circuit gating unit status word 1 / Gating unit ZSW1
VECTOR_G (Parallel) Can be changed: - Calculated: - Access level: 4
Data type: Unsigned16 Dyn. index: PDS, p0120 Func. diagram: -
P-Group: Displays, signals Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Fault time-critical ON OFF -
01 Gating unit mode bit 0 ON OFF -
02 Pulse enable ON OFF -
03 Upper switch-off signal path Inactive Active -
04 Lower switch-off signal path Inactive Active -
05 Gating unit mode bit 1 ON OFF -
06 Gating unit mode bit 2 ON OFF -
07 Brake state ON OFF -
08 Brake diagnostics ON OFF -
09 Armature short-circuit braking Active Not active -
10 Gating unit state bit 0 ON OFF -
11 Gating unit state bit 1 ON OFF -
12 Gating unit state bit 2 ON OFF -
13 Alarm status bit 0 ON OFF -
14 Alarm status bit 1 ON OFF -
15 Diagnostics 24 V ON OFF -
r7250[0...4] Par_circuit power unit rated power / PU P_rated
VECTOR_G (Parallel),
B_INF (Parallel)
Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Converter Unit group: 14_6 Unit selection: p0100
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [kW] - [kW] - [kW]
r7251[0...4] Par_circuit power unit rated current / PU PI_rated
VECTOR_G (Parallel),
B_INF (Parallel)
Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Converter Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]