2 Parameters
2.2 List of parameters
SINAMICS G130/G150
780 List Manual (LH2), 07/2016, A5E03263479A
Description: Displays the firmware and EEPROM versions of the DRIVE-CLiQ component selected using p7828[1].
Index: [0] = Reference firmware version
[1] = Actual firmware version
[2] = EEPROM0 version
[3] = EEPROM1 version
[4] = AndEEPROM2 version
[5] = EEPROM3 version
[6] = EEPROM4 version
Dependency: Refer to: p7828
Note: For index 0:
Firmware version on the memory card/device memory.
For index 1:
Actual firmware version of the DRIVE-CLiQ component.
For index 2 ... 6:
Actual EEPROM version of the DRIVE-CLiQ component.
Description: Sets the behavior for the automatic firmware update of the DRIVE-CLiQ components.
Value: 0: Deactivated
1: Upgrade and downgrade
2: Upgrade
Notice: If this parameter is changed, it only becomes effective the next time that the drive system boots.
Note: The firmware is automatically updated when the system boots. The boot can take several minutes.
After the update has been completed, it is necessary to carry out a new POWER ON (switch-off/switch-on) for the
components involved.
The firmware update procedure is displayed as follows:
Control Unit (LED RDY):
Flashes yellow with 0.5 Hz --> firmware is being updated.
Flashing yellow with 2 Hz --> POWER ON is required for the components involved.
Components involved:
Flashing red/green with 0.5 Hz --> firmware is being updated.
Flashing red/green with 2 Hz --> POWER ON of the components is required.
Only components from firmware version 2.5 support the red/green flashing at 2 Hz.
r7825[0...6] DRIVE-CLiQ component versions / DQ comp version
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
p7826 Firmware update automatic / FW update auto
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting