2 Parameters
2.2 List of parameters
[19] = Drive object number object 19
[20] = Drive object number object 20
[21] = Drive object number object 21
[22] = Drive object number object 22
[23] = Drive object number object 23
Notice: This parameter may only be used by qualified service personnel.
Note: If the same drive object numbers are used and if the existing drive object numbers in the system are entered
incompletely, the content of this parameter is ignored entirely. The behavior as with factory setting will then become
effective.
Description: Displays the sampling times currently present on the drive unit.
r7901[0...63]: sampling times of hardware time slices.
r7901[64...82]: sampling times of software time slices.
r7901[x] = 0, means the following:
No methods have been registered in the time slice involved.
Note: The basis for the software time slices is T_NRK = p7901[15].
Description: Displays the number of hardware sampling times that can still be assigned.
These free sampling times can be used by technology functions such as TEC, DCC or FBLOCKS.
Note: DCC: Drive Control Chart
FBLOCKS: free blocks
TEC: Technology Extension
Description: Sets the signal source for bit-serial input signals.
These signals are available in binector output r8510.0 ... 7 for further interconnection.
Index: [0] = To BO: r8510.0
[1] = To BO: r8510.1
[2] = To BO: r8510.2
[3] = To BO: r8510.3
[4] = To BO: r8510.4
[5] = To BO: r8510.5
[6] = To BO: r8510.6
[7] = To BO: r8510.7
Dependency: Refer to: r8510
r7901[0...81] Sampling times / t_sample
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [µs] - [µs] - [µs]
r7903 Hardware sampling times still assignable / HW t_samp free
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
p8500[0...7] BI: Input signal bit-serially 0 / Input_sig bit 0
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 2195
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0