Description: Sets the stop response for the function "Safely Limited Position" (SLP).
Value: 0: STOP A
1: STOP B
2: STOP C
3: STOP D
4: STOP E
10: STOP A with delayed stop response when the bus fails
11: STOP B with delayed stop response when the bus fails
12: STOP C with delayed stop response when the bus fails
13: STOP D with delayed stop response when the bus fails
14: STOP E with delayed stop response when the bus fails
Index: [0] = Limit value SLP1 (SE1)
[1] = Limit value SLP2 (SE2)
Dependency: Refer to: p9534, p9535
Note: In the extended sense, a bus failure should be seen here as a communication error in the control signals of the safety
functions (e.g. via PROFIsafe or TM54F).
SLP: Safely Limited Position
Description: Sets the stop response for the function "Safely Limited Speed" (SLS).
These settings apply to the individual limit values for SLS.
In the case of encoderless motion monitoring (p9506/p9306 = 1, 3), only a value of 0 or 1 is permitted.
Value: 0: STOP A
1: STOP B
2: STOP C
3: STOP D
4: STOP E
10: STOP A with delayed stop response when the bus fails
11: STOP B with delayed stop response when the bus fails
12: STOP C with delayed stop response when the bus fails
13: STOP D with delayed stop response when the bus fails
14: STOP E with delayed stop response when the bus fails
Index: [0] = Limit value SLS1
[1] = Limit value SLS2
[2] = Limit value SLS3
[3] = Limit value SLS4
Dependency: Refer to: p9331, p9380, p9563
Notice: This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note: In the extended sense, a bus failure should be seen here as a communication error in the control signals of the safety
functions (e.g. via PROFIsafe or TM54F).
SLS: Safely Limited Speed
p9362[0...1] SI Motion SLP stop response (Motor Module) / SI mtn SLP stop MM
VECTOR_G Can be changed: C2(95) Calculated: - Access level: 3
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: Safety Integrated Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 14 2
p9363[0...3] SI Motion SLS stop response (Motor Module) / SI Mtn SLS Stop MM
VECTOR_G Can be changed: C2(95) Calculated: - Access level: 3
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: Safety Integrated Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 14 2