EasyManua.ls Logo

Siemens G130 - p0151[0...1] DRIVE-CLiQ Hub Module component number; Hub comp_no; p0154 Terminal Module detection via LED; TM detection LED; p0154 DRIVE-CLiQ Hub Module detection via LED; Hub detection LED; p0155[0...n] Voltage Sensing Module activate;deactivate; VSM act;deact

Siemens G130
1976 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Parameters
2.2 List of parameters
SINAMICS G130/G150
98 List Manual (LH2), 07/2016, A5E03263479A
Description: This parameter is used to assign the data set to a DRIVE-CLiQ Hub Module.
This unique component number is assigned when parameterizing the topology.
Only the numbers of components operated as hubs can be entered in these parameters.
[0] = DRIVE-CLiQ node 1
[1] = DRIVE-CLiQ node 2
Description: Detects the Terminal Module assigned to this drive and data set.
Note: While p0154 = 1, the READY LED flashes green/orange or red/orange with 2 Hz at the appropriate Terminal Module.
Description: Detects any DRIVE-CLiQ Hub Module that has been assigned.
Description: Setting to activate/deactivate a Voltage Sensing Module (VSM).
Value: 0: Deactivate component
1: Activate component
2: Component deactivate and not present
Recommendation: After inserting a component, before activating, first wait for Alarm A01317.
Dependency: Refer to: r0156
Refer to: A01314, A01317
p0151[0...1] DRIVE-CLiQ Hub Module component number / Hub comp_no
HUB Can be changed: C1(4) Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: Data sets Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 199 0
p0154 Terminal Module detection via LED / TM detection LED
TM31, TM120, TM150,
TM54F_MA,
TM54F_SL
Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: Terminals Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0
p0154 DRIVE-CLiQ Hub Module detection via LED / Hub detection LED
HUB Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: Encoder Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0
p0155[0...n] Voltage Sensing Module activate/deactivate / VSM act/deact
VECTOR_G Can be changed: C1(4), T Calculated: - Access level: 2
Data type: Integer16 Dyn. index: p0150 Func. diagram: -
P-Group: Data sets Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 2 1

Table of Contents