SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
983
2 Parameters
2.2 List of parameters
Description: For index 0:
Displays the message value that resulted in the STOP F on the drive.
Value = 0:
The Control Unit signaled a STOP F.
Value = 1 ... 999:
Number of the incorrect date in the crosswise data comparison between the monitoring channels.
Value >= 1000:
Additional diagnostic values of the drive.
For index 1:
Displays the value of the Control Unit that resulted in the STOP F.
For index 2:
Displays the value from the second channel that resulted in the STOP F.
Index: [0] = Message value for CDC
[1] = Control Unit CDC actual value
[2] = Components CDC actual value
Dependency: Refer to: C01711
Note: The significance of the individual message values is described in message C01711.
CDC: Crosswise Data Comparison
For index 1, 2:
When Safety message C01711 with message value >= 1000 occurs, these indices are not supplied with values.
Description: Setting to select and de-select the user agreement.
Value: 0: [00 hex] De-select user agreement
172: [AC hex] Select user agreement
Dependency: Refer to: r9727
Description: Displays the internal state of the user agreement.
Value = 0: User agreement is not set.
Value = AC hex: User agreement is set.
Dependency: Refer to: p9726
r9725[0...2] SI Motion diagnostics STOP F / SI Mtn Diag STOP F
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Safety Integrated Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
p9726 SI Motion user agreement selection/de-selection / SI Mtn UserAgr sel
VECTOR_G Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: Safety Integrated Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0000 hex 00AC hex 0000 hex
r9727 SI Motion user agreement inside the drive / SI Mtn UserAgr int
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: Integer16 Dyn. index: - Func. diagram: 2822
P-Group: Safety Integrated Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -