Jumpers on TML8W
Figure 3-35 TML8W (S30817-Q626-Axxx/Bxxx)
LED states and their meaning
Table 3-27 TML8W - LED states
Red LED Green LED State Action
Off Off Board not receiving power / not plugged
in correctly.
Board is deactivated.
Check plug contact on board.
On Off Board is receiving power / board test in
progress.
Board is defective if state remains
unchanged (i.e. board test is
unsuccessful).
Replace board.
Loadware loading operation was not
successfully completed. Board is
defective.
Replace board.
Error was detected on board. Board is
deactivated (does not apply to
errors that were determined by loop tests)
/ board was deactivated by
Hicom Assistant E.
Check whether board was
deactivated by Hicom Assistant
E. If not, replace board.
Flashing Off Loadware is being loaded.
Hicom 150 E Office Rel.1.0 Service Manual - 3.3 Peripheral boards