During boot phase / initialisation
Flickering
(50/50 ms)
Board test unsuccessful Replace board
Flashing
(100/100 ms)
Board not configured Visual inspection, plug board in
or out if required.
Replace board if flashing
continues.
On Loading operation in progress
Flashing
(100/100 ms)
Code could not be loaded Replace board
Off Board loaded
Flashing
(500/500 ms)
Board loaded but not yet
activated
During operation
On Board seized
Flashing in ring cadence Board in ringing state
Flickering
(450/50 ms)
Dependability test (loopback test) in
progress
Flashing
(500/500 ms)
Board deactivated (e.g. S1 is in down
position)
Check whether board has been
deactivated by Hicom Assistant
E or by means of a lockout
switch.
Off Board in idle state, no seizure
Cable and SU connector assignment (backplane)
Table 3-30 TMOM - cable assignment
Colour
group
Pair a-wire b-wire SU conn. TMOM Notes
BP: X8
1 1 wht/blu 19 1a A1 TMON - PSE
interface
(see Figure 3-37)
blu/wht 39 1b B1
2 wht/ora 38 2a C1
ora/wht 48 2b D1
3 wht/grn 27 3a E1L
grn/wht 47 3b E1H
4 wht/brn 16 4a M1L
brn/wht 46 4b M1H
5 wht/gry 05 5a A2
gry/wht 45 5b B2
2 6 red/blu 14 6a - Relay contacts
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_32.htm (34 of 46) [06/04/2000 13:03:54]