3.3.14 4SLA / 8SLA / 16SLA
Introduction
The subscriber line modules 4SLA/8SLA/16SLA (subscriber line analog) for analog a/b interfaces are
used in OfficeCom/OfficePoint for connecting conventional standard telephones as well as
supplementary equipment (e.g. group 3 fax machines and ET adapters).
Interfaces
Figure 3-48 4SLA/8SLA interfaces (S30810-Q2925-X)
Table 3-35 4SLA/8SLA contact assignments
Contact X2 (a/b ports 1-4) X3 (a/b ports 5-8)
1 a 1 a 5
2 b 1 b 5
3 a 2 a 6
4 b 2 b 6
5 a 3 a 7
6 b 3 b 7
7 a 4 a 8
8 b 4 b 8
The 16SLA subscriber line module for 16 analog a/b interfaces is used in OfficeCom/OfficePoint for
connecting conventional standard telephones as well as supplementary equipment (e.g. group 3 fax
machines and ET adapters).
Hicom 150 E Office Rel.1.0 Service Manual - 3.3 Peripheral boards
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_32.htm (44 of 46) [06/04/2000 13:03:55]