Figure 3-52 EXM interfaces (S30817-Q902-Bxxx)
Table 3-38 EXM contact assignments
Contact Connector X1 Connector X2
1 GND Port
2 Free Port
3 Free Free
4 EXMCL Free
5 EXMDIR
6 HRES
7 EXMD
8 EXMDET
9 +5V
10 Free
3.4.3 GEE8
Introduction
Call charge pulses can be recorded by plugging the call metering receiving equipment (GEE8, 12/16
kHz) into the TML8W board (Hicom 150 E OfficePro).
The connection is established by means of the X10 and X11 connections.
Switch for setting the level per circuit
On = - 24 dBm
Off = - 10 dBm
Switch on GEE8
Hicom 150 E Office Rel.1.0 Service Manual - 3.4 Options
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_33.htm (3 of 16) [06/04/2000 13:04:11]