If one or two extension cabinets are required in addition to the basic cabinet, the four metal
connecting plates will ensure that the protective earth conductor connections of these cabinets are
connected.
The various protective earthing options are displayed in Figure 4-7 and later.
Danger
An authorized service technician is to be commissioned to earth the system by using option
1b (Figure 4-8) or 2 (Figure 4-9) if you or your colleagues are not sufficiently qualified to
perform work on low-voltage networks (230 V AC).
Earthing concept for the system cabinet(s) and the main distribution frame
Figure 4-6 Hicom 150 E OfficePro - earthing concept for the system cabinet(s) and the main
distribution frame
Protective earthing option 1a
Hicom 150 E Office Rel.1.0 Service Manual - 4 Installation
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_4m.htm (10 of 27) [06/04/2000 13:04:41]