Figure 4-17 View of the dual board connector for flash and modem cards on the CBMOD
Insert the FMC into the left-hand board of the CBMOD
(see Figure 4-17).
Insert the IMOD (if installed) into the right-hand board of the CBMOD
(see Figure 4-17).
Information on the different CBMOD issues must not be ignored.
Insert the CGM module (if available) in the socket provided on the CBMOD.
4.1.12 Configuration information
Introduction
The cabinet(s) is (are) already equipped with customised boards when the system is delivered.
Board slots
Eight board slots are available in each cabinet. The following boards are assigned permanent slots:
CBMOD central processor board -> slot 01 in the BC
CONBO connection board (three-cabinet system only) -> slot 17 in EC2
PSUI power supply unit -> slot 08 in the BC, slot 16 in the EC1, slot 24 in the EC2.
Slot 09 in EC1 should remain free.
Peripheral boards can be inserted into slots 02 - 07 in the BC, 10 - 15 in EC1 and 18 - 23 in EC2 (the
adhesive label beneath the slots identifies each slot) depending on their installation width (see Figure
4-18).
An SLMO board must be inserted in the first slot for peripheral boards (BC, slot 02) since
system administration can only be performed via an optiset E device.