1
The mode (EPSON or IBM) is determined solely on the basis of DIP switches 1-4. There is no control code to select
the mode.
2
DC1 code = printer selection via software, DC3 code = printer deselection via software.
3
CR and LF are activated if , CR only if .
DIP switch series 1, switches 1-1 to 1-3
Table 6-3 P 500 printer -
DIP switch series 1,
switches 1-1 to 1-3
Country Switch no.
1-1 1-2 1-3
USA Off Off Off
France Off Off On
Germany Off On Off
England Off On On
Denmark On Off Off
Sweden On Off On
Italy On On Off
Spain On On On
DIP switch series 1
Table 6-4 P 500 printer - DIP switch series 2
Function Switch no. 1200 b/s 2400 b/s 4800 b/s 9600 b/s
Serial transmission speed 2-1 Off On Off On
2-2 Off Off On On
Function Switch no. XON/XOFF Ready/In use
Serial printer selection 2-3 On Off
Function Switch no. No parity Uneven
parity
Even parity
Parity 2-4 Off Off On On
2-5 Off On Off On
Function Switch no. 7 bits 8 bits
Serial data length 2-6 On Off
Function Switch no. Serial interface Parallel interface
Interface
selection
2-7 On Off
Function Switch no. Selected Non selected