Note the following points:
Position of the connecting cable between the cabinets
(Figure 4-13)
CONBO board slot = slot 17 in EC2
The four terminating resistors (board-side, between slots 19 + 20 and 23 +
PSUI) on the backplane of EC2 are to be removed.
Distribution of the PCM sequence in Figure 4-22.
CBMOD issues
If Then
CBMOD =
S30810-Q2960-X
Remote administration and maintenance not possible via the integrated digital
modem (B channel access).
The integrated modem card, IMOD, must be inserted to permit remote
administration and maintenance.
CBMOD =
S30810-Q2960-X100,
< issue 3
The integrated modem card, IMOD, must not be inserted in the case of ISDN
systems. Otherwise, remote administration and maintenance is not possible
with the integrated digital modem (B channel access).
CBMOD =
S30810-Q2960-X100,
issue 3
Remote administration and maintenance is possible both via the integrated
modem card, IMOD, and the integrated digital modem (IMOD).
Using flash memory carts
Only Siemens AG Flash Memory Cards FMC may be used. Flash memory cards from other
manufacturers are not specified and do not guarantee correct operation.
Using peripheral boards
Table 3-45 shows which boards from Hicom 150 E Releases 1.0, 2.0, 2.1 can be used in
Hicom 150 E Office Release 1.0.