RPN
(port number)
Number of the base station, i. e. BS port number in the SLMC8 (0 - 7). If the MT
switches to an overlapping radio cell/BS, the number of the new base station is shown
in the MT display.
Procedures: deactivating the radio quality measurement
Step Entry/key MT display
1. Press the on/off/protect key for at least 2 s until the MT display is blank.
12.5.3 Result documentation
Data to be documented
The installation site of the base stations must be included in a building/site plan.
If possible, the length of the connection cable from the BS to Hicom 150 E OfficePro must be
recorded next to every base station.
The range of the radio cells must be included in the building/site plan.
Subsequent structural changes in the radio range (buildings, sites, facilities and
devices, etc.) may affect operation of the mobile telephones and thus some base
stations may have to be rearranged.
The form "Configuration: Hicom cordless, Version 1" (order no. A31003-X81-X1-*-62) is to
be filled out and confirmed by the customer.
12.6 Testing the Hicom cordless 150 E
components
12.6.1 Checking the base station BS
Determining the status of the BS at the MT or optiset E terminal with display
CMI diagnosis Entry Display
Hicom 150 E Office Rel.1.0 Service Manual - 12 Cordless Multicell Integration CMI
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_12.htm (18 of 45) [06/04/2000 13:05:56]