Outdoors
When installing a BS outdoors, it must be placed in the outdoor casing.
The heating board for regulating the temperature in the outdoor casing has not yet been
released for operation with Hicom cordless 150 E Version 1.0!
DO NOT connect the heating board! This could cause the system to malfunction due to
self-heating.
The station can be mounted on a wooden, plastic or cement mast (not a steel mast) on the roof of a
building (preferably of brick or lightweight materials) or on the wall of a building.
When selecting the site, it must be ensured that there is a line of sight from the BS to as large a part of
the coverage area as possible.
The regulations relating to lightning protection for the installation medium must be taken into
consideration.
When mounting a BS on a mast, the mast's resistance to the wind must be guaranteed.
BS arrangement: BS with outside casing
Hicom 150 E Office Rel.1.0 Service Manual - 12 Cordless Multicell Integration CMI
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_12.htm (35 of 45) [06/04/2000 13:05:56]