Table 13-7 Error class 09 - hardware errors
No. Meaning Recovery
action
Technician
action
0 Microprocessor (error occurred) Reload board Replace brd
1 Microprocessor (no error) None None
2 Loadware memory (error occurred) Reload board Replace brd
3 Loadware memory (no error) None None
12 Signal failure (error occurred) None Replace brd
13 Signal failure (no error) None None
22 Clock reference (error occurred) None Replace brd
23 Clock reference (no error) None None
29 Line interruption (error occurred) Disable board Replace brd
30 Short circuit (error occurred) Disable board Replace brd
31 Low voltage (error occurred) Disable board Replace brd
32 Thermal overload (error occurred) Disable board Replace brd
34 Frame loss on STMD (error on) Disable board Replace brd
35 Frame loss on STMD (error off) None None
36 Data slip on STMD (error on) Disable board Replace brd
37 Data slip on STMD (error off) None None
38 Alarm display error TMS2M (error on) Disable board Replace brd
39 Alarm display error TMS2M (error off) None None
42 No signal TMS2M (error on) Disable board Replace brd
43 No signal TMS2M (error off) None None
44 Receive remote alarm TMS2M (error on) Disable board Replace brd
45 Receive remote alarm TMS2M (error off) None None
48 Bit slip on TMS2M (error on) Disable board Replace brd
49 Bit slip on TMS2M (error off) None None
50 Loss of synchr. on TMS2M (error on) Disable board Replace brd
51 Loss of synchr. on TMS2M (error off) None None
58 Self-test SLMO (error on) Disable board Replace brd
59 Self-test SLMO (error off) None None
61 Overcurrent check SLMO on Disable board Replace brd
62 Overcurrent check SLMO off None None
Error class 15 -APS
Table 13-8 Error class 15 - APS
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_13.htm (11 of 19) [06/04/2000 13:06:54]