2. 14-11 => Extension Data Menu - Extension Type
3. Configure data security
* 9531994
4. 14-16 => Extension Data Menu - Data Security
Programming Feature Via Hicom Assistant E
Configure the feature via Hicom Assistant E as follows:
Step Action
1. Options
2. Set up station
3. Station
4. Param
5. Flags
Performing Feature Check
Check the feature for error-free functioning as follows:
Step Action
1. Set up a call from a telephone on which `Data Security' has been activated.
2. Call the extension.
3. The camp-on tone is not signalled. The extension receives the `busy' tone.
7.10.2 Date and Time Display
Definition
The system contains a real-time clock and a calendar function. Each optiset E terminal with a display
indicates the time and date information from this clock. In the case of digital trunk lines, the time and
date are automatically set if the relevant information is transmitted by the CO.
The changeover from standard time to daylight saving time (and vice versa) is performed
automatically.
If there is no synchronisation option via the ISDN CO, the changeover data is implemented via a table
in the system. The table can be updated by means of Hicom Assistant E.
Model-Specific Data
Subject OfficePro OfficeCom OfficePoint OfficeOne
Feature available in x x x x
HW requirements U
P0/E
terminal with display
SW requirements As of Rel. 1.0 As of Rel. 1.0 As of Rel. 1.0 As of Rel. 1.0