Code lock While the code lock is activated, you cannot activate any features with the
exception of system speed-dialling, babyphone, voice calling and
conferences with internal extensions.
Configuration options
The feature can be configured using:
Hicom Assistant T / Hicom Assistant E
Programming Feature Via Hicom Assistant T
Configure the feature via Hicom Assistant T as follows:
Step Action
1. Enter subscriber class of service
*9531994
2. 22-19-2 => System Options - Lock all phones
3. Define number for the extension that can activate the system code lock.
Programming Feature Via Hicom Assistant E
Configure the feature via Hicom Assistant E as follows:
Step Action
1. Enter subscriber class of service
Options
2. System Parameters
3. System settings
Performing Feature Check
Check the feature for error-free functioning as follows:
Step Action
1. Lock the terminal using the input procedure.
2. Depending on the setting, you cannot place any external calls after you have programmed the
system.
7.3.4 Hotline
Definition
A connection is set up automatically to a predefined internal or external destination after you lift the
handset.
You can also configure the feature so that the connection is set up only after a defined period of time
Hicom 150 E Office Rel.1.0 Service Manual - 7.3 Features for general outgoing traffic
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_73.htm (4 of 6) [06/04/2000 13:10:06]