3. Select relevant extension
4. Enter name
5. Configure group names
*9531994
6. 16-15-3 => Call Management Inc - Group Setup - Group Name
7. Select relevant group
8. Enter name
9. Configure routes
*9531994
10. 17-15 => Call Management Out - Route Name
11. Select relevant route
12. Enter name
Programming Feature Via Hicom Assistant E
Configure the feature via Hicom Assistant E as follows:
Step Action
1. Configure extension names
Options
2. Set up station
3. Station
4. Change name for relevant station
5. Configure group names
Options
6. Incoming Calls
7. Hunt group
8. Enter name for the relevant group
9. Configure routes
Options
10. Lines / networking
11. Routes
12. Enter name for the relevant route
Performing Feature Check
Check the feature for error-free functioning as follows:
Step Action
1. Configure an extension name.
2. Call the extension from another internal terminal with a display.
Hicom 150 E Office Rel.1.0 Service Manual - 7.8 Features for internal traffic