1. Call the internal number of another networked extension.
7.11.3 Toll Restriction with CorNet N
Definition
Hicom 150 E Office supports satellite PABX traffic via CorNet N. In this regard, the system can be
operated as an end node (system without main CO, only CorNet trunk group), transit node (system
with at least 2 CorNet trunk groups, no CO) and a gateway (system with CO and CorNet trunk group).
In addition to basic call functionality (outgoing and incoming call setup), the toll restriction feature is
also supported.
If Hicom 150 E Office is being operated within networked environments, the trunk access assigned to
the extension is checked and transferred or received in the incoming route when a CorNet N line is
seized (transfer of trunk access). Trunk access is transferred to a gateway system each time an
outgoing line is seized and each time a call is answered at an extension with the usual procedure.
Model-Specific Data
Subject OfficePro OfficeCom OfficePoint OfficeOne
Feature available in x x _ _
HW requirements - - - -
SW requirements As of Rel. 1.0 As of Rel. 1.0 _ _
Dependencies/Limitations
Subject Dependency/Limitation
Restrictions There are only four restriction types for COS transfer:
internal access, outward-restricted, LPN, unrestricted trunk access
Configuration options
The feature can be configured using:
Hicom Assistant T / Hicom Assistant E
Programming Feature Via Hicom Assistant T
Configure the feature via Hicom Assistant T as follows:
Step Action
1. Configure trunk access
*9531994
2. 15-1 => Call Barring Menu - Trunk Access Day
3. 15-2 => Call Barring Menu - Trunk Access Night
4. 15-3 => Call Barring Menu - Allowed Lists
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_711.htm (4 of 17) [06/04/2000 13:11:33]