Figure 3-1 OfficeCom/OfficePoint CBFC interfaces (S30810-Q2950-X)
Table 3-3 LEDs H1-H10 and their meaning
LED (green) Meaning LED (red) Meaning
H 2 Slot 2 H 1 Slot 2
H 4 Slot 3 H 3 Slot 3
H 6 Slot 4 * H 5 Slot 4 *
H 8 Slot 5 * H 7 Slot 5 *
H 9 RUN LED
H 10 IMOD LED
* see Figure 4-27 and Figure 4-29
LED signalling concept see also Section 13.3.1 and Section 13.3.2.2
CBFC contact assignment (OfficeCom/OfficePoint)
Table 3-4 Contact assignments (OfficeCom/OfficePoint)
Contact Conn. X1 Conn. X2 Conn. X3 Conn. X4
1 a1 - Port 1 a 1 - Port 1 GND
2 b1 - Port 1 b 1 - Port 1 Free
3 a2 - Port 2 a 2 - Port 2 Free
Hicom 150 E Office Rel.1.0 Service Manual - 3.2 Central boards