CO feature x x x x
Extension feature x x x x
Dependencies/Limitations
Subject Dependency/Limitation
MCID Malicious call ID works with external calls and QSIG lines but not with
CorNet-N.
MCID Release of the lines is delayed.
QSIG With QSIG, activation is possible in the active state only.
MCID The "malicious call ID" class of service can be programmed for individual
extensions.
MCID internal to S
0
Activation is forwarded to the CO.
Configuration options
The feature can be configured using:
Hicom Assistant T / Hicom Assistant E
Programming Feature Via Hicom Assistant T
Configure the feature via Hicom Assistant T as follows:
Step Action
1. Configure MCID
* 9531994
2. 14-22 => Extension Data Menu - MCID
Programming Feature Via Hicom Assistant E
Configure the feature via Hicom Assistant E as follows:
Step Action
1. Configure MCID
Options
2. Station Parameter
3. Station
4. Param
5. Flags
Performing Feature Check
Check the feature for error-free functioning as follows:
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_713.htm (9 of 16) [06/04/2000 13:11:54]