8.6 Configuring toll restriction per extension
Introduction
For each extension, 15 levels of toll restriction are available:
0 = No toll restriction *)
1 = Only incoming calls are permitted. *)
2-7 = Only the digits entered in allowed lists 1 to 6 can be dialled. *)
8-13 = Digits entered in barred lists 1 to 6 cannot be dialled. *)
14 = Full access, no restrictions
*) System speed-dialling destinations can be dialled without restriction.
Allowed number list:
One allowed list (allowed list 1) with 45 positions
5 additional allowed lists (allowed lists 2 to 6) with 10 positions each
Class of service 2 corresponds to allowed list 1, class of service 3 corresponds to allowed list 2, etc.
Example
The extension with extension number 250 is in class of service 2 and during the day can access only
the emergency numbers (110 and 112) via lines 1 and 2.
Programming with Hicom Assistant T
Step Entry Action Display
1. *95 31994 Start system administration System Administration
2. 15-1 Trunk access, day Ext 200, Trk 1: full
3.
# 250
Select extension 250 Ext 250: as for ext 200
4.
* 2
Enter new data Ext 250, Trk 1:
5.
2
Allowed list 1 for line 1 Ext 250, Trk 1: E-L 1
6.
+ * 2
Allowed list 1 for line 2 Ext 250, Trk 1: E-L 1
7. F7 Return to Call Barring Menu Call Barring Menu
8. 3-1 Select allowed list 1 Pos 1: -
9.
* 110
Enter extension number 110 Pos 1: 110
Hicom 150 E Office Rel.1.0 Service Manual - 8.6 Configuring toll restriction per extension