8.14 Configuring an intercept extension per line
Introduction
In the case of systems with different basic accesses, it may be necessary to configure a separate
intercept position for each basic access. This is performed by means of call allocation per line.
If a number of intercept position are configured, the intercept position (day and night) must
be cancelled. An undialled line cannot be switched.
Example
Lines 1 and 2 (1st S
0
basic access) are to be allocated to extension 200.
Lines 3 and 4 (2nd S
0
basic access) are to be allocated to extension 300.
Programming with Hicom Assistant T
Step Entry Action Display
1. *95 31994 Start system administration System Administration
2. 16-12 Select Intercept, Day Call No.: 200
3.
*
Delete Intercept, Day Call No.: -
4. F2 Select Intercept, Night Call No.: 200
5.
*
Delete Intercept, Night Call No.: -
6. F7 16 Select Non DID,Day Trk 1: 200
7. + + Select trunk 3 Trk 3: 200
8.
* 300
Enter station 300 Trk 3: 300
9.
+ * 300
Enter station 300 Trk 4: 300
10. F7 17 Select Non DID,Night Trk 1: 200
11. + + Select trunk 3 Trk 3: 200
12.
* 300
Enter station 300 Trk 3: 300
13.
+ * 300
Enter station 300 Trk 4: 300
14. F8-F7 Exit system administration Set time, Set date