8.18 Configuring an internal S0 bus with multiple
extensions
Introduction
Each S
0
bus can support up to 8 terminals or telephones. For this purpose, one or more system ports
must be configured as a ISDN bus.
Example
Port 4 is to be configured as a ISDN bus.
Programming with Hicom Assistant T
Step Entry Action Display
1. *95 31994 Start system administration System Administration
2. 20 -4-1
ISDN Parameter Menu, EU Parameter Menu, S
0
Port
Config.
Port 1: ISDN Public PP
3.
# 4
Select Port 4 Port 4: ISDN Public PP
4.
* 4
Configuration as an ISDN bus Port 4: ISDN Bus
5. F8-F7 Exit system administration Set time, Set date
Programming with Hicom Assistant E
Step Action
1. Options -> Lines / networking -> Trunks -> Flags
Note
LS numbers must now be assigned for each telephone or terminal connected to the ISDN bus. How
the LS is set on the telephone depends on the particular phone.
If no LS is assigned for the telephones, the default setting for this port is used as the LS for all
telephones, i.e. when this default LS is called, all the telephones connected to the bus are called.
See also Section 5.2.8
| Siemens | Home | First Page | Previous Page | Next Page | Search | Info | Help |
© Siemens AG, München, 1998
Hicom 150 E Office Rel.1.0 Service Manual, 2, 1998-06-26
Siemens Part No.: P31003-M1530-X403-2-7620
Hicom 150 E Office Rel.1.0 Service Manual - 8.18 Configuring an internal S0 bus with multiple extensions
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_818.htm (1 of 2) [06/04/2000 13:13:12]

Table of Contents

Other manuals for Siemens Hicom 150 E Office

Related product manuals