4. F8-F7 Exit system administration Set time, Set date
Programming with Hicom Assistant E
Step Action
Cannot be configured with the tool!
Example
The password for remote DTMF administration is to be changed. This password is freely configurable
in Hicom 150 E Office.
Step Entry Action Display
1. *95 Start "User data" from system administration User data
2. 20 Activate Code, RMA Old code:
3. ******
(old code,
000 000)
Enter old code (default 000 000) New code:
4. *** ***
(new code)
Enter new code Repeat:
5. *** ***
(repeat new code)
Confirm new code New code saved
6. F8-F7 Exit User data menu
Remote DTMF administration can be performed via analog and digital trunks. It can be
started only from the first or second port of the destination system (slave system).
| Siemens | Home | First Page | Previous Page | Next Page | Search | Info | Help |
© Siemens AG, München, 1998
Hicom 150 E Office Rel.1.0 Service Manual, 2, 1998-06-26
Siemens Part No.: P31003-M1530-X403-2-7620
Conversion Date: 1998-09-18
Hicom 150 E Office Rel.1.0 Service Manual - 8.26 Remote administration via DTMF