15. F8 33-1 Display number of queued calls Amount: 15
16.
* 2
Change number of queued calls to 2 Amount: 2
17. F2 Display speed transfer mode Mode: Denied
18.
* 1
Release speed transfer mode Mode: Allowed
19. F2 Display transfer undialled trunk Mode: Denied
20.
* 1
Release transfer undialled trunk Mode: Allowed
21. F8 16-18-1 Display CM-Targets List 1, Mbr 1: Call
22.
# 13 +
Select call destination list 13, Mbr 2 List 13, Mbr 2: -
23.
* 13
Change Mbr 2 to 13 List 13, Mbr 2: 13
24.
F2 #12
Display assignment of internal call to call destination
list
Call No. 12: 16
25.
* 13
Change to call destination list 13 Call No. 12: 13
26. F2 Display assignment of external call (day) to call
destination list
Call No. 12: 14
27.
* 13
Change to call destination list 13 Call No. 12: 13
28. F8-F7 Exit system administration Set time, Set date
Programming with Hicom Assistant E
Step Action
1. Options -> System Parameters -> Diversion / VPL
2. Options -> Incoming Calls -> Call destination lists
3. Options -> Incoming Calls -> Assignment int./ext. calls
Note
The "Release", "Call" and "Trunk group" keys should be programmed at the AC.