8.37 COS changeover after timeout
Introduction
Least cost routing allows you to change trunk access on the basis of timers for each extension.
Example
All extensions should have unrestricted trunk access on route 1 on Monday between 00:00 and
16:00.
As of 16:00, only extension 100 should have unrestricted trunk access on route 1. All others
should have outward-restricted trunk access.
Programming with Hicom Assistant T
Step Entry Action Display
1. *95 31994 Start system administration System Administration
2. 35-1 Activate Least Cost Routing Routing On/Off
3.
*1
Activate Least Cost Routing State: on
4. F7 3-1 Assign name for outdial rule Name - Line 1:
5.
*BUM
Enter name Line 1: COSX
6.
F2 * A
Enter format for outdial rule Line 1: A
7.
F2 * 2
Set type for outdial rule to 1layer mode Line 1: 1layer mode
8. F7 F7 5-1 * 1600
Set Length of time 1 for "Day index 1"
(Monday) to 16:00
Day index 1, Pos 1: 1600
9.
F2 *1
Length of time 1 is assigned time period 1
(zone A in the tool)
Day index 1 Pos 1: 1
10.
ok * 2
Length of time 2 is assigned time period 2
(zone B in the tool)
Day index 1 Pos 2: 2
11.
F7 F7 6 + *14
Extension 101 is assigned class of service 14,
all others are assigned 15.
Ext 101: 14
12.
F7 7-1 *1
Route table 1 is assigned route 1 Tab 1, Line 1: 1
13.
F2 * 1
Route table 1 is assigned outdial rule 1 Tab 1, Line 1: 1
14.
F2 * 14
Route table 1 is assigned class of service 14 Tab 1, Line 1: 14
Hicom 150 E Office Rel.1.0 Service Manual - 8.37 COS changeover after timeout