Operation as announcement
Announcement type: announcement
Relay 1: type: announcement - time: 5 x 100 ms - extension: a/b call number
Relay 2: type: after timeout - time: n x 100 ms - extension: a/b call number
(n x 100 ms = length of the announcement)
Programming via Hicom Assistant T
Step Entry Action Display
1. *95 31994 Start system administration System Administration
2. 26-1 Select type Actr No. 1: -
3.
* 20
"Announcement" type Actr No. 1: Announcement
4. + Next actuator Actr No. 2: -
5.
* 12
"After timeout" type Actr No. 2: After timeout
6. F7 Return to: Actuators
7. 2 Select react time Actr No. 1: 255
8.
* 5
React time actuator 1 (5 = 5ms) Actr No. 1: 5
9. + Next actuator Actr No. 2: 255
10.
* 200
React time actuator 2 (200 = 20s) Actr No. 2: 200
11. F7 Return to: Actuators
12. 3 Enter the call number of announcement port under
"Assigned ext"
Actr No. 1: -
13.
* 124
Announcement port call number for actuator 1 Actr No. 1: 124
14. + Next actuator Actr No. 2: -
15.
* 124
Announcement port call number for actuator 2 Actr No. 2: 124
16. F7 / F8
17. 14-11 Enter the station type as the default Ext 11: default
18.
# 124
Enter the extension Ext 124: default
19. F8-F7 End system administration Set time, set date
| Siemens | Home | First Page | Previous Page | Next Page | Search | Info | Help |
© Siemens AG, München, 1998
Hicom 150 E Office Rel.1.0 Service Manual, 2, 1998-06-26
Siemens Part No.: P31003-M1530-X403-2-7620
Conversion Date: 1998-09-18
Hicom 150 E Office Rel.1.0 Service Manual - 8.40 Mozart CD/Genius announcement device at the SLA board
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_840.htm (2 of 2) [06/04/2000 13:14:46]

Table of Contents

Other manuals for Siemens Hicom 150 E Office

Related product manuals