Table 3-10 Contact assignment of AUI interface
X3
10-pole
Western socket
15-pole
SUB-D socket
Function
1 9 Collision detect: - wire
2 2 Collision detect: + wire
3 12 Receive: - wire
4 5 Receive: + wire
5+6 1+4+8+11+14 GND(AUI)
7 10 Transmit: - wire
8 3 Transmit: + wire
9 6 GND(AUI)
10 13 +12V AUI - power supply voltage
(11+12) Shielding GND(AUI)
Table 3-11 Contact assignment of
10Base-T interface
X4
8-pole Western socket
Function
1 Transmit: + wire
2 Transmit: - wire
3 Receive: + wire
6 Receive: - wire
4+5+7+8 Not used
3.3.2 SLA16
Introduction
The SLA16 (subscriber line module analog) peripheral group provides 16 analog a/b interfaces for
Hicom 150 E OfficePro.
Switches and LEDs
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_32.htm (2 of 46) [06/04/2000 13:03:52]