Technical connection requirements
Max supply current approx. 34 mA, supply voltage approx. 40 V DC
Ring voltage against negative supply voltage (a-wire/RING) for max. two telephones
Range approx. 2 x 750ohms (overall resistance)
Loop detection > 10 mA
Earthing key detection > 20 mA
The transmission settings (see Section 2.6.1) are configured on a country-specific basis using
the relevant country code.
3.3.3 SLMC8
Introduction
The SLMC8 (subscriber line module cordless) board allows a maximum of eight base stations to be
connected to Hicom 150 E OfficePro (this configuration allows a maximum of 32 simultaneous
connections of the active subscriber).
The SLMC8 has a unique ID and may only be used once to equip a Hicom 150 E OfficePro
system with Hicom cordless 150 E.
Inserting the SLMC8 releases 16 mobile units for use (PIN numbers are assigned). These
mobile units can then be logged on to the system. Any additional mobile units to be used
must be released first.
Base stations must be clocked with a high degree of accuracy as a prerequisite for Hicom cordless 150
E operation. The CGM plug-in type module on the CBMOD board must be used for this purpose.
Switches and LEDs
Figure 3-16 SLMC8 (S30810-Q2911-X)
LED states and their meaning
Table 3-14 SLMC8 - LED states
Red LED Green LED State Action