Off Off Board not receiving power / is not
plugged in correctly.
Board is deactivated.
Check plug contact on board.
On Off Board is receiving power / board test in
progress.
Board is defective if state remains
unchanged (i.e. board test was
unsuccessful).
Replace board.
Error detected on board. Board is
deactivated (does not apply to errors
detected in test loops) / board was
deactivated by Hicom Assistant E.
Replace board.
Error detected on board. Board is
deactivated (does not apply to errors
detected in test loops) / board was
deactivated by Hicom Assistant E.
Check whether board was
deactivated by Hicom Assistant
E. If not, replace board.
Flashing Off Loadware is being loaded.
Off On Loading operation was successfully
completed / board is operational (idle
state).
Off Flashing At least one extension is activated.
Cable and SU connector assignment (backplane)
Table 3-15 SLMC8 - cable assignment
Colour
group
Pair a-wire b-wire SU conn. SLMC8 Notes
BP: X8
1 1 wht/blu 19 1a Access 1 Base station 1
blu/wht 39 1b
2 wht/ora 38 2a Access 2 Base station 2
ora/wht 48 2b
3 wht/grn 27 3a Access 3 Base station 3
grn/wht 47 3b
4 wht/brn 16 4a Access 4 Base station 4
brn/wht 46 4b
5 wht/gry 05 5a Access 5 Base station 5
gry/wht 45 5b
2 6 red/blu 14 6a Access 6 Base station 6
blu/red 44 6b
7 red/ora 23 7a Access 7 Base station 7
ora/red 43 7b