Flashing
(100/100 ms)
Board not configured Visual inspection, plug board in or out
if required.
Replace board if flashing continues.
On Loading operation in progress
Flashing
(100/100 ms)
Code could not be loaded Replace board
Off Board loaded
Flashing
(500/500 ms)
Board loaded, but not yet activated
During operation
On ISDN layer 2 activated
Flickering
(450/50 ms)
Dependability test (loopback test) in progress
Flashing
(500/500 ms)
Board deactivated (e.g. S300/x "closed") Test whether board was deactivated by
means of Hicom Assistant E or lockout
switch.
Off ISDN layer 2 not activated
Cable and SU connector assignment (backplane)
Table 3-21 STMD8 - cable assignment
Colour
group
Pair a-wire b-wire SU conn. STMD8 Notes
BP: X8
1 1 wht/blu 19 1Ea Basic
access 1
Receive
(3/4 TAE8 / 4/5 MW8)
blu/wht 39 1Eb
2 wht/ora 38 1Sa Transmit
(6/5 TAE8 / 3/6 MW8)
ora/wht 48 1Sb
3 wht/grn 27 2Ea Basic
access 2
Receive
(3/4 TAE8 / 4/5 MW8)
grn/wht 47 2Eb
4 wht/brn 16 2Sa Transmit
(6/5 TAE8 / 3/6 MW8)
brn/wht 46 2Sb
5 wht/gry 05 3Ea Basic
access 3
Receive
(3/4 TAE8 / 4/5 MW8)
gry/wht 45 3Eb
2 6 red/blu 14 3Sa Transmit
(6/5 TAE8 / 3/6 MW8)
blu/red 44 3Sb
7 red/ora 23 4Ea Basic
access 4
Receive
(3/4 TAE8 / 4/5 MW8)
ora/red 43 4Eb
8 red/grn 32 4Sa Transmit
(6/5 TAE8 / 3/6 MW8)
grn/red 42 4Sb
Hicom 150 E Office Rel.1.0 Service Manual - 3.3 Peripheral boards