EasyManua.ls Logo

Siemens HiPath 1130 - Number of Attempts for Activating the Sensor; DTMF Signals for the Relay

Siemens HiPath 1130
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Relay and Sensor on the HiPath 1120
131
Step by Step
Number of Attempts for Activating the Sensor
This setting specifies the number of call attempts
(between 1 and 100) for the number specified in
"Number Dialed by Sensor Activation." (See also Time
between Attempts for Activating the Sensor).
An attempt is made after every call that was not
answered (busy signal), or when the "Detect DTMF
Code" option (Code 70, Option 3) is enabled and no
acknowledgment is received. When this occurs, the call
is disconnected and a new attempt is made.
By default, only one attempt is made.
Required: Programming Mode must be active (*95
31994).
Enter the code for programming.
... Enter the number of attempts (001 to 100).
Initial state for Programming Mode.
DTMF signals for the Relay
This setting specifies a number sequence that is
converted to DTMF signals and sent after a call is
answered. The number to be called must be specified
in "Number Dialed by Sensor Activation" (Code 052).
The default configuration does not specify any number.
Required: Programming Mode must be active (*95
31994).
Enter the code for programming.
Enter the number sequence (up to 20 digits).
Press this key.
Initial state for Programming Mode.
0 5 3
0 1
0
0 01
7 7
#

Table of Contents

Other manuals for Siemens HiPath 1130