EasyManua.ls Logo

Siemens HiPath 1150 - Assigning a Class of Service (COS)

Siemens HiPath 1150
241 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Step by step
Important settings
32
dkf w Enter the programming code.
q or r w To activate/deactivate the permission:
q = Activated
r = Deactivated (default)
w Initial status for programming mode.
Assigning a class of service (COS)
Required: Programming mode must be activated (*95
31994).
eee w Enter the programming code.
p w Enter the number for the group of external lines (e.g., 0,
890...899).
p w Enter a class of service for day mode and another for
night mode:
1st digit defines the input for day service class
2nd digit defines the input for night service class
Classes of service:
d = Restricted
e = Outward-restricted trunk access with Denied
List 1
(10 slots)
f = Outward-restricted trunk access with Denied
List 2
(25 slots)
g = Outward-restricted trunk access with Denied
List 3
(35 slots)
h = Outward-restricted trunk access with permis-
sion list 1
(10 slots)
i = Outward-restricted trunk access with permis-
sion list 2
(25 slots)
j = Outward-restricted trunk access with permis-
sion list 3
(25 slots)
k = Unrestricted Trunk Access (default for all lines)

Table of Contents