Operating
7.12 Open Channel Monitoring (OCM)
HydroRanger 200 HMI
Operating Instructions, 06/2018, A5E36281317-AC
143
7.12.4.3
Palmer-Bowlus flume
Flow
Upper scaling point
Transducer
1)
Zero head (2.13.4.5.) (Page 244)
Empty (2.2.4.) (Page 170)
D = pipe or sewer diameter
Span (2.2.2.) (Page 169)
D/2, point of measurement
2)
Parameter
Mode
Primary Measuring Device (2.13.2.)
(Page 240)
Palmer-Bowlus
PMD Dimensions (2.13.5.) (Page 246)
OCM Dimension 1 (2.13.5.1.)
(Page 246)
Flume width (D)
Maximum Head (2.13.4.2.) (Page 243)
Maximum Head
Maximum Flow (2.13.4.3.) (Page 243)
Maximum Flow
Zero Head (2.13.4.5.) (Page 244)
Zero Head
Flow Time Units (2.13.4.4.) (Page 244)
Time Units
Application information
Sized by pipe diameter D
Flume relief is trapezoidal
Designed to install directly into pipelines and manholes
Head is referenced to bottom of the throat, not bottom of the pipe
For rated flows under free flow conditions, the head is measured at a distance of D/2
upstream from the beginning of the converging section.