INHAB™ ENERGY INSTALLATION GUIDE 
Troubleshooting Tips
Here are some of our most frequent troubleshooting tips. For more help, call the
Siemens Technical Support number at ---.
The Siemens app is not finding the Inhab Energy after I’ve installed it.
Ensure the Inhab Energy has power:
- Check for a flashing Wi-Fi light.
- Listen for a startup tone.
- Check the wire harness is secure and wired properly.
- Check that the main breaker is turned on.
- Check that the breaker powering the Inhab Energy is turned on.
Ensure your phone connect to the Inhab Energy.
- Check your phone’s Bluetooth is on.
- If you’re using an Android, turn on Location Services for your phone to
properly scan for Bluetooth devices.
- If you’re using an iPhone, make sure Bluetooth is allowed in the Settings >
Siemens Inhab Energy app > Bluetooth allowed
Ensure the Inhab Energy’s Wi-Fi antenna has been installed properly.
- Check the antenna is properly screwed into the energy monitor
- Ensure the antenna is outside of the electric panel. It’s ok if it is inside a wall,
just ensure it’s not inside the metal box.
Ensure the Inhab Energy’s wired LAN connection is installed properly
- Check that the ethernet cable is securely connected to the Inhab Energy’s
LAN port
- Check that the ethernet cable is securely connected to a router, switch, or
modem
- Ensure the network does not have a firewall preventing new devices from
accessing the internet
Try power cycling the breaker to which the Inhab Energy is connected.
Try restarting the Siemens App.
Try rebooting your phone.
The Siemens Inhab Energy app isn’t getting real-time data from the Inhab
Energy
Ensure all current transformers are securely fastened around their respective
cables in the electric panel.
Check the screw terminal plugs are securely plugged into the ports of the
energy monitor.
Check that the CT wires are securely connected to the screw terminals and that
the screws are tight