Fitting the wall spacer
Fig. +
If available:
Fit wall spacers to obtain the indicated
energy rating of the appliance.
A reduced wall gap will not restrict
the function of the appliance. The energy
rating may then increase slightly.
Distance to the back wall
The distance of 75 mm must not be
exceeded.
Aligning the appliance
Place the appliance in the designated
location and align.The appliance must be
level and stand securely on the floor. If
the floor is uneven, use the front height-
adjustable feet. Adjust the height-
adjustable feet with a spanner.
Note
The appliance must be vertical. Please
align it with a spirit level.
Observe ambient
temperature
and ventilation
Ambient temperature
The appliance is designed for a specific
climate class. Depending on the climate
class, the appliance can be operated at
the following temperatures.
The climate class can be found on
the rating plate. Fig. )
Note
The appliance is fully functional within
the room temperature limits
of the indicated climatic class. If
an appliance of climatic class SN
is operated at colder room temperatures,
the appliance will not be damaged up to
a temperature of +5 °C.
Ventilation
Fig. $
The air on the rear panel and on the side
panels of the appliance heats up.
Conduction of the heated air must
not be obstructed. Otherwise,
the refrigerating unit must work harder.
This increases power consumption.
Therefore: Never cover or block
the ventilation openings!
Climate class Permitted ambient
temperature
SN +10 °C to 32 °C
N +16 °C to 32 °C
ST +16 °C to 38 °C
T +16 °C to 43 °C