Installation instructions en
31
20.3 Installation below a worktop
Observe the installation dimensions and the installation
instructions when installing below a worktop.
¡ To ventilate the appliance, the intermediate floor
must have a ventilation cut-out.
¡ In combination with induction hobs, the gap
between the worktop and appliance must not be
sealed using additional strips.
¡ The worktop must be secured to the fitted unit.
¡ Observe any available installation instructions for the
hob.
¡ Observe different national installation instructions for
the hob.
20.4 Installation underneath a hob
If the appliance is installed under a hob, the following
minimum dimensions must be adhered to (including
substructure, if applicable).
The minimum worktop thickness a is based on the
required minimum clearance ⁠.
Hob type a raised in mm a flush in mm b in mm
Induction hob 39 40 5
Full-surface induction hob 49 50 5
Gas hob 29 40 5
Electric hob 29 32 2
20.5 Installation in a tall unit
Observe the installation dimensions and the installation
instructions when installing in a tall unit.
¡ To ventilate the appliance, there must be a gap of
20mm between all intermediate floors and the wall.
¡ If the tall unit has another back panel in addition to
the element back panels, this must be removed.