en Installation instructions
50
31.4 Installation underneath a hob
If the appliance is installed under a hob, the following
minimum dimensions must be adhered to (including
substructure, if applicable).
The minimum worktop thickness a is based on the
required minimum clearance ⁠.
Hob type a raised in mm a flush in mm b in mm
Induction hob 37 38 5
Full-surface induction hob 47 48 5
Gas hob 27 38 5
1
Electric hob 27 30 2
1
Observe different national installation instructions for the hob.
31.5 Installation in a tall unit
Observe the installation dimensions and the installation
instructions when installing in a tall unit.
¡ To ventilate the appliance, the intermediate floors
must have a ventilation cut-out.
¡ In order to ensure sufficient ventilation of the appli-
ance, there must be a ventilation opening of at least.
200cm² in the base area. To do this, trim the base
panel or fit a ventilation grille. Ensure that the air ex-
change is guaranteed in accordance with the dia-
gram.
¡ If the tall unit has another back panel in addition to
the element back panels, this must be removed.
¡ Only fit the appliance up to a height which allows
accessories to be easily removed.